Applications
- Environmental: Lost Sources, Contamination
- Emergency Response: Nuclear Incident Response Teams
- Security: Customs, Military
- Geophysical, Uranium, Gas & Oil Exploration
Key Unique Features
- Accurate “the first time” technology
The advanced digital design using FPGA/DSP technology and signal processing provides a more stable operation, with less drift, producing a pure spectra that results in better data for you. In addition to the externally recorded data, the RS-700 series records internally the last 24 hours that can be easily retrieved if required. - Effectively no Dead-time as each crystal has it’s own A/D converter within it’s own ADS
- 1024 channel resolution for any number of crystals at up to 10x per second
- Menu selectable 1024, 512 or 256 channel output
- Individual crystal ADC and processing resulting in improved pulse pile-up rejection, zero dead time, and a higher throughput
- Virtually no distortion, each crystal output is fully linearised permitting multi-crystal summing without distortion
- Effectively no signal degradation when summing an unlimited number of crystals – common on most current systems
- No radioactive test sources required for system setup. or for system performance validation
- Extremely wide dynamic range 250,000 cps for each crystal providing >20x improvement on signal throughput compared to older systems
- High level of self diagnostics with sophisticated error correction & reporting requiring less operator interaction
- Fully multi-peak automatic gain stabilisation on natural isotopes for world wide use
RadAssist Software with mapping & Nuclide Identification features
RadAssist is a suite of utilities, running under Windows XP providing the user with control and monitoring capabilities. The software operates in real-time or in playback mode. Along with the functions above, the following outlines some of the additional features;
- Set-up menus for operational parameters
- Display and Monitoring:
- 4 channel chart display with selectable items
- Spectral waterfall excellent for highlighting
- Navigation track with ‘breadcrumb’ trail
- Contour plot
- Mapping displays with selectable data overlays.
- Nuclide identification
- Alarm capability
TECHNICAL SPECIFICATIONS
Spectrometer | |
Channels | 1024 |
Differential nonlinearity | < 0.2% over top 99.5% |
Integral nonlinearity | < 0.01% over top 99.5% |
Zero dead time1 | ✔ |
Baseline restoration | Digital (IPBR)2 |
Pulse shaping | Digital (AOPS)3 |
Pile-up rejection | Digital(<40nS) |
Pile-up contamination | < 1% @ 250Kcps |
Sample rate | 0.1-10 sec-1 |
Timing Internal/External Gain stabilisation |
Automatic multi-peak |
I/O | Ethernet RS-232 19200-115200 bit/s bit/s USB memory stick |
Outputs | |
Composite spectrum | ✔ |
Individual spectra | ✔ |
State of health | ✔ |
Inputs | |
Detector configuration | ✔ |
Operational parameters | ✔ |
Trigger Signal | ✔ |
Calibration data | ✔ |
Gamma Detector | |
RSX-1 | 4L Nal(TI) |
RSX-3×3 | 0.4L Nal(TI) |
Energy resolution | <8.5%4 |
Neutron Detector | |
Tube size |
2” dia x 32” active length 3He
|
Tube pressure |
2.7 atm (no transportation limits)
|
Moderator |
Medium moderated for optimum performance
|
Power | |
RSX-1 & RSX 3×3 |
9-40 VDC, 6W
|
RS-701 Console |
15W
|
Weight | |
RSX-1 |
22.7 kg
|
RSX 3×3 |
6.8 kg
|
RS-701 Console |
6.8 kg
|
NSX-4/4 |
27 kg
|
Rooftop Carrier |
9 kg
|
Size | |
RSX-1 |
731 mm x 162 mm x 172 mm
|
RSX-3×3 |
381 mm x 101 mm x 101 mm
|
NSX-4/4 |
1,176 mm x 177 mm x 177 mm
|
RS-701 Console |
233 mm x 112 mm x 198 mm)
|
Environmental | |
Operating Temperature |
-30°C to +45°C
|
- The RS-700 has no dead time in a traditional sense. A live time clock will be adjusted for loss of system measured pile-up rejections to give an apparent dead time to ensure the absolute count rate is correct.
- IPBR – Individual Pulse Baseline Restoration. The baseline is established for each individual pulse for maximum pulse height accuracy.
- AOPS – Automatic Optimised Pulse Shaping. Pulses are continuously analysed and the signal pulse shaping adjusted for optimum performance.
- Stated energy resolution is for new systems. Refurbished system performance depends on quality of Xtals supplied.